General specifications | ||
Switching element function | NAMUR, NC | |
Rated operating distance | 0.2 mm | |
Installation | flush | |
Output polarity | NAMUR | |
Assured operating distance | 0 ... 0.2 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 100 Hz | |
Hysteresis | typ. % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | ≤ 1 mA | |
Functional safety related parameters | ||
MTTFd | 11770 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR |
EN 60947-5-6:2000 IEC 60947-5-6:1999 |
|
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Products with a maximum operating voltage of ≤36 V do not bear a CCC marking because they do not require approval. | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Axial load, max. | 0 ... 1200 N | |
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Special steel | |
Protection degree | IP67 |